How To Skip Device Register Clearos

ClearBOX 300 Userguide

ClearBOX 300 is a robust gateway and server appliance designed for pocket-sized and medium business and distributed enterprise. Information technology comes with or without wireless support. Information technology includes network featherbed functionality which allows for some robust and high availability applications.

For information about ClearBOX in general, please refer to the ClearBOX general guide. This guide is for ClearBOX 300 specific operations and issues.

Features

This technical guide is meant to help engineers in specific needs and high level configuration options for ClearBOX 300 series of appliances. Delight click hither for a general overview of features listed in ClearBOX 300.

Ports and Functions

The port above the USB is a serial port.

Looking at the front of the ClearBOX from left to correct are the post-obit:

  • eth0

  • eth1

  • eth2

  • eth3

  • eth4

  • eth5

  • serial0(ttyS0)

  • USB0

  • USB1

  • display

  • display controls

eth0: First Ethernet port. Configured for External by default and set to DHCP (Internet access provider)

eth1: 2nd Ethernet port. Configured for LAN by default and set to 192.168.one.one

eth2: unconfigured

eth3: unconfigured

eth4: unconfigured

eth5: Sixth Ethernet port. Configure for LAN by default with DHCP running. This port is useful for those that want to configure their ClearBOX without an initial monitor. Set up to 172.22.22.22 and can be accessed at https://172.22.22.22:81

serial0: This port looks similar an ethernet port but is in fact a Serial Comm port and can be used for console access, modems, or serial heartbeat in high availability modes.

USB0: This is a USB two.0 port that can exist used for keyboard input, USB storage, or whatever other Linux capable USB purpose.

USBone: This is a USB two.0 port that tin can be used for keyboard input, USB storage, or any other Linux capable USB purpose.

Display: LCD display shows a double asterisk when the eziod service is Non running.

Display controls:

ClearBOX 300 bypass

The ClearBOX 300 controls its featherbed unit of measurement through the BIOS, you volition need to modify the BIOS settings of ClearBOX 300 to back up the Inline Transparent Content Filter mode or the Mission Critical Gateway fashion.

Indicator Calorie-free Status
Green NICs on featherbed segment are active and traffic to each NIC is distinct.
Red NICs are beingness bypassed, the signal is being coupled.
Blackness The NICs are physically unreachable/offline and the point is not being bypassed.

ClearBOX Gen1 and Gen2

To enable the bypass on ClearBOX Generation 1 or Generation 2, enter the BIOS at power on by pressing the Delete key. Navigate to Advanced > Onboard Featherbed Control. For Transparent Content Filtration Bridge, set Group ane to "Non-Normal, BPE: Enable". For Mission Disquisitional Gateway set both Grouping 1 and Group 2 to "Non-Normal, BPE: Enable" (this is only required for the backup unit). If you lot are changing a previously configure bypass to regular modes without bypass support, set the Group to "Normal, BPE: Disable". for each of the 2 bypass segments (For mission critical gateway support). To relieve these settings, press <Escape> until you reach the Advanced screen. Then navigate to Go out and select Save Changes and Exit. Yous will know that the bypass is working past the land of the bypass indicator light adjacent to the eth0 jack.

ClearBOX Gen3 and Gen 4

To enable the bypass on ClearBOX Generation 3, boot the system to the control prompt. Ensure that the eziod module is installed:

yum install eziod

Adjacent, decide your featherbed system directory:

ls /sys/bus/i2c/devices/
vi-0022/ 6-0026/ i2c-0/  i2c-1/  i2c-2/  i2c-three/  i2c-4/  i2c-v/  i2c-6/

Hither you tin come across the two bypass segments every bit detected by the driver:

  • 6-0022 (bypass1)

  • half-dozen-0026 (bypass0)

To manipulate the condition of the BIOS for the bypass segment, echo the desired value to the nextboot0 parameter:

  • 0=bypass disabled (light-green)

  • ane=bypass enabled (red)

For case, if you wanted your backup server to boot with bypass enabled (required for mission disquisitional installations), perform the following:

echo 1 > /sys/motorcoach/i2c/devices/6-0022/nextboot0 echo one > /sys/bus/i2c/devices/half-dozen-0026/nextboot0

Featherbed technical

Contained of the BIOS, the bypass is controlled and manipulated at the Bone level by echoing values into the controls located on they /sys partition.

  • bypass0

    • 0=featherbed disabled (green)

    • i=bypass open up (black)

    • 2=bypass enabled (red)

  • period0

    • configurable to the number of seconds for the watchdog timer to expire

  • wdt0

    • 0=disable watchdog timer (default)

    • 1=enable watchdog timer

Decide ClearBOX type

ClearBOX 300 Gen 3 was introduced in Q4 of 2012. Any boxes purchased before Q4 2012 are Gen1 or Gen 2. Generation 3 ClearBOX 300 uses Intel i7 processors. To decide if your ClearBOX is Gen3 run the following:

[root@organization ~]# true cat /proc/cpuinfo |grep "model proper noun" model proper noun	: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz model name	: Intel(R) Core(TM) i7-2600 CPU @ iii.40GHz model proper noun	: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz model name	: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz model name	: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz model name	: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz model proper noun	: Intel(R) Core(TM) i7-2600 CPU @ iii.40GHz model name	: Intel(R) Core(TM) i7-2600 CPU @ three.40GHz

ClearBOX Gen1 and Gen2

The locations of the sys controls for Generation 1 and 2 ClearBOX are located at:

  • Bypass1

    • /sys/motorbus/i2c/devices/0-0026/

  • Bypass2

    • /sys/bus/i2c/devices/0-0022/

ClearBOX Gen3

The locations of the sys controls for Generation 3 ClearBOX are located at:

  • Bypass1

    • /sys/bus/i2c/devices/14-0026/

  • Bypass2

    • /sys/bus/i2c/devices/14-0022/

Thermal Cruise Mode

ClearBOX 300 is shipped past default in Thermal Cruise Mode which means that the fans will step upwardly their speed commensurate with the oestrus of the processor. This is useful for situations where the ClearBOX may be used in environments which are sensitive to besides much noise. This mode also helps preserve the longevity of the fans and reduces the amount of grit that tin can accrue inside ClearBOX.

This mode is non as appropriate for heavy use applications like virtualization or heavy apply under large content filtration, web services, or database loads. To modify this setting, enter the BIOS and naviagate to Advanced > Hardware Wellness Configuration. Alter the three fans to Manual Mode to enable the fans at total speed all the time.

BIOS Update

A BIOS update exists for ClearBOX 300 Gen1 which brings more features to aggrandize retentivity and processor options. Essentially it transforms a Gen1 box to a Gen2 box. There is no update path from Gen1/two to Gen3. Contact support for more than information.

Setting ClearBOX to factory defaults

To set ClearBOX 300 to manufactory defaults perform the post-obit:

BIOS Reset

To gear up the BIOS to shipping condition, connect a VGA monitor and USB keyboard to the advisable ports on ClearBOX and power on. Printing the 'Delete' central on your keyboard until it enters the BIOS SETUP UTILITY. Use the keyboard arrows to navigate the carte du jour. Yous can printing Enter to make selections and the 'Escape' key to back out of a bill of fare.

Defaults

Navigate to the 'Leave' menu. Under this menu select 'Load Optimal Defaults'. When prompted with 'Load Optimal Defaults?', select 'Ok' and press 'Enter'. Once the default settings are loaded, make the post-obit additional changes.

Fans

Next, re-enter the BIOS SETUP UTILITY and navigate to the Avant-garde menu. Navigate further to the Hardware Health Configuration section. Under this section, set the following for all values:

  • Fans: Mode Setting

    • values to '[Thermal Cruise Manner]'

  • all TargetTemp Value

    • settings to '[055]'

  • all Tolerance Value

    • settings to '[03]'.

ClearBOX Generation 1 and ii

Boot Options

Next, validate that the Boot settings in the Boot card are prepare to:

Hard disk Drives
  • 1st Drive should be:

    • [SATA:3M-SanDisk SD]

  • 2d Bulldoze should start with (ignore Xs):

    • [SATA:PM-XXXXXXXXXX]

  • third Drive (on dual drive systems):

    • [SATA:SM-XXXXXXXXXX]

Boot Device Priority
  • 1st Boot Device should be:

    • [SATA:3M-SanDisk SD]

  • 2nd Kicking Device should be:

    • [Network:IBA GE Slo]

ClearBOX Generation 3

As with the ClearBOX Gen1 and 2, the ClearBOX Gen3 apparatus boots primarily from the Meaty Flash before handing boot control over to the configured local hard drive. This ensures that the recovery tools and installation media is always available. To set up the Compact Flash equally the get-go boot media, navigate to the boot section and set the 1st Kick device equally [CF HDD: SanDisk SD…] (see image below)

Operating System Reset

ClearBOX comes with a Compact Flash or USB which contains the installation that your ClearBOX shipped with. To re-install the operating organisation attach a VGA monitor and USB keyboard and ability on the organization. Later the BIOS completes, they organization will launch to a bill of fare on the Compact Flash. This menu is on a 5 second filibuster and will go along to kicking the organization unless interrupted. You can stop the countdown past pressing the arrow keys in the menu.

For USB and for Compact Flash installations where the boot media is not the primary target in the BIOS, you can press 'B' on your keyboard during the boot wheel to boot off of the USB.

The following can erase all data on your ClearBOX. Delight fill-in your data before proceeding

From the installation menu, you lot can re-install your ClearBOX by navigating the bill of fare and selecting the advisable install option. On some models of ClearBOX, you can 're-install' the system which will format the operating system division and go out the bindmount information volume alone.

Considerations

ClearBOX improvements and development continues. This ways that you can upgrade your ClearBOX to a newer version past simply replacing the Compact Flash or USB that came installed or included. Simply enter the menu and do a fresh install. Delight contact the sales department for data on obtaining an upgraded Compact Flash or USB for your ClearBOX and any licensing upgrades that may besides apply.